張家港油研變量柱塞泵中文樣本YUKEN泵特點
oils or R & O (Rust and Oxidation inhibitor) type hydraulic
oils equivalent to ISO VG-32 or 46. The recommended
viscosity range is from 20 to 400 mm2/ s (98 to 1800 SSU)
and temperature range is from 0 to 60°C (32 to 140°F),
both of which have to be satisfied for the use of the abov
2. Control of Contamination
Due caution must be paid to maintaining control over
contamination of the operating oil which can otherwise lead
to breakdowns and shorten the life of the unit. Please
maintain the degree of contamination within NAS Grade
The suction port must be equipped with at least a 100 mm
(150 mesh) reservoir type filter and the return line must
have a line filter of under 10 mm.
3. Mounting
When installing the pump the filling port should be
positioned upwards.
4. Alignment of Shaft
Employ a flexible coupling whenever possible, and avoid
any stress from bending or thrust.
Maximum permissible misalignment is less than 0.1 mm (.
004 inches) TIR and maximum permissible misangular is
less than 0.2°.
5. Suction Pressure
Permissible suction pressure at inlet port of the pump is
between -16 and +50 kPa (5 in.Hg Vacuum and 7 PSIG).
For piping to the suction port, use the pipes of the same
diametre as that of the specified pipe flange to be used.
Make sure that the height of the pump suction port is
within one metre (3.3 ft) from the oil level in the reservoir.
6. Hints on Piping
When using steel pipes for the suction or discharge ports,
excessive load from the piping to the pump generates excessive
noise.
Whenever there is fear of excessive load, please use rubber
hoses.
7. Suction Piping
In case the pump is installed above the oil level, the
suction piping and suction line filter should be located
lower than the pump position to prevent air in the suction
line.
Install drain piping according to the chart and ensure that
pressure within the pump housing should be maintained
at a normal pressure of less than 0.1 MPa (14.5 PSI) and
surge pressure of less than 0.5 MPa (72.5 PSI).
Length of piping should be less than 1 m (3.3 ft.), and the
pipe end should be submerged in oil.