目錄:上海希言科學儀器有限公司>>美國戴安Dionex>> 美國戴安 P/N: 039686Dionex CarboPac PA1 Carbohydrate Column 生物色譜柱

Dionex CarboPac PA1 Carbohydrate Column 生物色譜柱
  • Dionex CarboPac PA1 Carbohydrate Column 生物色譜柱
參考價 面議
具體成交價以合同協議為準
參考價 面議
具體成交價以合同協議為準
  • 品牌 DIONEX/英國
  • 型號 美國戴安 P/N: 039686
  • 廠商性質 代理商
  • 所在地 上海
屬性

>

更新時間:2018-04-16 01:25:16瀏覽次數:1255評價

聯系我們時請說明是化工儀器網上看到的信息,謝謝!

同類優質產品

更多產品
戴安公司生產的儀器主要有離子色譜儀、高效液相色譜儀、快速溶劑萃取儀和氨基酸直接分析儀。其中離子色譜儀憑借著雄厚的技術優勢和方法已廣泛地應用于各個領域,其*達80%。與離子色譜相關的文章有90%均出自戴安公司生產的離子色譜儀。   
戴安公司的快速溶劑萃取儀15分鐘之內僅用15毫升溶劑既可完成對10g樣品的萃取,該技術已在環境、藥物、食品和聚合物工業等領域得到廣泛應用。

Ideal Column for the Separation of Neutral and Acidic Monosaccharides

The CarboPac? PA1 is an anion-exchange column for the separation of mono-, disaccharides, and specific oligosaccharides using an isocratic eluent. Sialic acid analysis has also been demonstrated on this column. 

  • General-purpose column for isocratic determination of monosaccharides and disaccharides
  • Detection by pulsed amperometric detection; no derivatization needed
  • Approved for use in a variety of official methods for the analysis of foods

The unique MicroBead? pellicular structure of the CarboPac PA1 resin gives it stability from pH 0–14 at all concentrations of buffer salts. The pellicular resin structure allows excellent mass transfer resulting in fast gradient reequilibration.

The CarboPac PA1 column is used with pulsed amperometric detection; no derivatization is required. Sensitivity on the PA1 is not as high as with the CarboPac PA20 or PA10 for monosaccharide analysis. Thus the CarboPac PA1 is well suited for the analysis of foods for nutritional labeling. The CarboPac PA1 has been approved for use in a number of official methods.

CarboPac PA1 Column for Routine Carbohydrate Analysis  Specifications
DimensionsCarboPac PA1 Analytical Column:
4 × 250 mm and 2 × 250 mm
CarboPac PA1 Guard Column:
4 × 50 mm and 2 × 50 mm
CarboPac PA1 Semipreparative Column:
22 × 250 mm
Maximum operating pressure4000 psi (27.9 MPa)
Temperature range4–55 °C
Recommended operating temperature: ambient
Typical operating conditions1500 psi at 1.0 mL/min (analytical and guard columns)
Recommended flow rate: 1.0 mL/min (for 4 × 250 mm)
phase compatibilitypH 0–14; up to 2% of common HPLC solvents.
Acetate or hydroxide eluents only.
Resin composition10-?m-diameter substrate (polystyrene 2% cross-linked with divinylbenzene) agglomerated with 500-nm MicroBead quaternary ammonium functionalized latex (5% cross-linked).
Anion-exchange capacityApproximay 100 ?eq/column (4 × 250 mm analytical column)
Column constructionPEEK with 10-32 threaded-ferrule-style end fittings.
All components are nonmetallic.
Analytical Columns
CarboPac PA1 Analytical Column (2 x 250 mm)057178
CarboPac PA1 Analytical Column (4 X 250 mm)035391
CarboPac PA1 Semi-Preparative Column (9 x 250 mm)039686
CarboPac PA1 Semi-Preparative Column (22 x 250 mm)SP2866
Guard Columns
CarboPac PA1 Guard Column (2 x 50 mm)057179
CarboPac PA1 Guard Column (4 x 50 mm)043096
CarboPac PA1 Guard (9 x 50 mm)063501

會員登錄

請輸入賬號

請輸入密碼

=

請輸驗證碼

收藏該商鋪

標簽:
保存成功

(空格分隔,最多3個,單個標簽最多10個字符)

常用:

提示

您的留言已提交成功!我們將在第一時間回復您~
在線留言

會員登錄

請輸入賬號

請輸入密碼

=

請輸驗證碼

收藏該商鋪

該信息已收藏!
標簽:
保存成功

(空格分隔,最多3個,單個標簽最多10個字符)

常用:
熱線電話 在線詢價
主站蜘蛛池模板: 枣阳市| 白玉县| 平阳县| 靖江市| 西昌市| 石家庄市| 荣昌县| 武隆县| 靖远县| 永新县| 肇东市| 平陆县| 无为县| 秦皇岛市| 苏尼特左旗| 吉林市| 靖宇县| 桐柏县| 合水县| 来安县| 彰化县| 井研县| 温泉县| 达拉特旗| 洛宁县| 南召县| 松阳县| 乌海市| 阿瓦提县| 乌恰县| 益阳市| 西林县| 扬中市| 黔西| 清新县| 同德县| 黄浦区| 铅山县| 广汉市| 易门县| 湄潭县|