性做久久久久久坡多野结衣-性做久久久久久久久浪潮-性欲影院-性影院-国产精品线路一线路二-国产精品兄妹在线观看麻豆

您好, 歡迎來到化工儀器網

| 注冊| 產品展廳| 收藏該商鋪

15601682291

products

目錄:上海鉑勒機電設備有限公司>>水質分析儀器>>其他水質分析儀及配件>> 5440003

5440003
  • 5440003
參考價 面議
具體成交價以合同協議為準
參考價 面議
具體成交價以合同協議為準
  • 品牌
  • 型號
  • 廠商性質 生產商
  • 產品資料 下載
  • 所在地 上海市
屬性

>

更新時間:2025-03-09 08:25:20瀏覽次數:689評價

聯系我們時請說明是化工儀器網上看到的信息,謝謝!

同類優質產品

更多產品
Industry standard, CL17 Free Chlorine Analyzer with AquaTrend Network. Included with the CL17 analyzer is a 1 month supply of DPD indicator and Free Chlorine indicator and buffer solutions, an install

Accurate, Reliable Results

The Hach CL17 Chlorine Analyzer uses colorimetric DPD chemistry to monitor water continuously for free or total residual chlorine. The CL17 is a simple, dependable and economic solution, and the preferred choice to high-maintenance instruments that require frequent calibration. The CL17 analysis method is robust and not affected by changes in chlorine concentration, sample pH, temperature, flow, or pressure, thus offering more accuracy and reliability than alternative instruments and technologies.

Simple, Predictable Maintenance

Monthly routine maintenance for the CL17 can typically be performed in 15 minutes and includes changing reagents and cleaning the colorimetric cell. No special tools are required. For typical use, the CL17 will operate unattended for 30 days. Challenging applications may require more frequent cleaning.

Factory Calibrated

The CL17 Chlorine Analyzer is factory calibrated. A built-in electronic calibration curve is preprogrammed into the instrument. This instrument does not require recalibration unless specified by your regulatory agency for compliance reporting purposes.

EPA Compliant

The CL17 is compliant with US EPA regulation 40 CFR 140.74, and both Method 4500-CL G and Method 334.0 can be used for measurement of residual chlorine in drinking water.

Pump Control

Both an alarm for manual chlorine feed control and a 4-20 mA output for automatic control of chlorine feed pumps is available on the CL17 Analyzer.

What's in the box

Hach CL17 Chlorine Analyzer with AquaTrend Circuit Board, a one-month supply of reagents, 100 mL of Sulfuric acid, Maintenance kit, Installation kit, and Manual. (The power cord is ordered separay.)

Specifications

Accuracy:± 5 % or ±0.03 mg/L (ppm) as CL2, whichever is greater

Air Purge:0.1 cfm (0.17 m³/h) instrument quality air at max. 20 psig (ca. 1.4 bar)

Alarm:Two alarms selectable for sample concentration alarm, analyzer system warning, or analyzer system shut-down alarm. Each is equipped with an APDT relay with contacts rated for 5A resistive load at 230 V AC.

Certifications:CE Approved
ETL Listed to UL 1262
ETL Certified to CSA 22.2 No. 142

Cycle Time:2.5 minutes

Dimensions (H x W x D):37.1 in x 16.5 in x 7.5 in (943 mm x 419 mm x 191 mm)

Display:LCD, 3-1/2 inch digit measurement readout and six-character alphanumeric scrolling text line

Drain:1/2-inch ID flexible hose, hose barb

Enclosure Construction:ABS plastic, two clear polycarbonate windows, IP62-rated with the gasketed door latched.

Inlet:1/4-inch OD polyethylene tube, quick-disconnect fitting

Interferences:Other oxidizing agents such as bromide, chlorine dioxide, permanganate and ozone will cause a positive interference. Hexavalent chromium will cause a positive interference: 1 mg/L Cr?? = approximay 0.02 mg/L as Cl?. Hardness must not exceed 1,000 mg/L as CaCO?.

Light Source:Class 1 LED (light emitting diode) with a peak wavelength of 520 nm; 50,000 hours estimated minimum life

Lower Limit of Detection (LOD):0.03 mg/L (ppm)

Mounting:Wall mount

Operating Humidity:90% at 40 °C (90% at 104 °F) maximum

Operating Temperature Range:5 to 40 °C (41 to 104 °F)

Power Requirements (Amps):2.5 A

Power Requirements (Hz):50/60 Hz

Power Requirements (Voltage):100 - 115/230 V AC

Pressure Limit:Inlet Pressure to Sample Conditioning: 1.5 to 75 psi (0.1 bar to 5.2 bar)

Range:0 to 5 mg/L free or total residual chlorine

Ranges:0 to 5 mg/L free or total residual chlorine

Repeatability:0.01 ppm or 3.0 % , whichever is greater

Sample Flow Rate:200 to 500 mL per minute minimum required

Sample Temperature:5 to 40 °C (41 to 104 °F)

Weight:24.91 lbs. (11.3 kg)

- See more at: http://www.hach.com/cl17-free-chlorine-analyzer-with-aquatrend-network/product-details?id=7640295863&callback=qs#sthash.hQR8UA9t.dpuf

會員登錄

請輸入賬號

請輸入密碼

=

請輸驗證碼

收藏該商鋪

標簽:
保存成功

(空格分隔,最多3個,單個標簽最多10個字符)

常用:

提示

您的留言已提交成功!我們將在第一時間回復您~
在線留言

會員登錄

請輸入賬號

請輸入密碼

=

請輸驗證碼

收藏該商鋪

該信息已收藏!
標簽:
保存成功

(空格分隔,最多3個,單個標簽最多10個字符)

常用:
熱線電話 在線詢價
主站蜘蛛池模板: 丹阳市| 文山县| 台北县| 五莲县| 贵州省| 崇阳县| 荔波县| 弥勒县| 红安县| 顺昌县| 临颍县| 宁国市| 台南市| 乌鲁木齐县| 长泰县| 综艺| 天门市| 邯郸县| 贵溪市| 宾阳县| 崇仁县| 杨浦区| 金溪县| 泸溪县| 阳朔县| 屯门区| 新乡县| 承德市| 旺苍县| 平泉县| 修武县| 罗定市| 云南省| 思茅市| 大厂| 浙江省| 宿松县| 白银市| 巴楚县| 邵阳县| 左权县|